Safety Information

Please select your product to view its manual

Product Information


Original MEATER®
Charger Battery Alkaline AAA

Battery Nominal Voltage 1.5V

Charger Battery Size AAA Single cell and measures 10.5 mm (0.41 in) in diameter and 44.5 mm (1.75in) in length

Charger Battery Quantity 1

Charger Model Number MT-ME01

Probe Model Number MT-PR00

Probe Battery Nominal Voltage 2.4V

Probe Capacity 3mAh

Operating Frequency 2402-2480MHz

Importer Name & Address: Seabreeze Supply Co. 6 Grevillea Street Byron Bay NSW 2481

Read All Instructions Before Using


Please read this entire manual before using your MEATER product. Failure to follow these instructions could result in property damage, bodily injury, or even death. If you are assembling this product for someone else, provide this manual for the owner to read and save for future reference.

Burn Hazard


Failure to follow the warnings below may cause the MEATER probe to explode and lead to serious injury or burns.

Always insert the MEATER probe past the safety notch (the minimum insertion point) to avoid product damage and personal injury.

DO NOT use the probe when cooking at temperatures above 527°F / 275°C, or when cooking directly above hot coals or flame.

DO NOT place the MEATER charging unit directly on the grill cover, or too close to any hot surface.

DO NOT remove the probe while it is exposed to heat. The probe must be inserted in and removed from food away from all heat sources.

Always use eye protection when removing a probe that has exceeded the maximum temperature or come in contact with hot charcoals or direct flames

If the probe falls into the fire or direct heat source, turn off the cooking appliance and close the lid immediately. Allow the probe to cool completely before removing.

DO NOT allow the probe to come in contact with hot charcoal or coals.

The probe will be hot during and after use. Wear heat-resistant gloves when handling the probe.

Foodborn Illness Hazard


Consuming raw or undercooked meats, poultry, or seafood may increase your risk of foodborne illness. Always cook your food to USDA safe temperatures.

Product Damage Hazard


Failure to follow the warnings below may cause the MEATER probe to explode and lead to serious injury or burns.

Always insert the MEATER probe past the safety notch to avoid damage.

DO NOT use the probe in a microwave or pressure cooker.

DO NOT place the MEATER charging unit on any hot surface.

DO NOT drop the probe onto hard surfaces.

DO NOT use cleaning products containing alcohol, ammonium, benzene, or abrasives, all of which could damage the device.

DO NOT use cleaning products containing alcohol, ammonium, benzene, or abrasives, all of which could damage the device

DO NOT run the probe under cold water immediately after cooking. Let the probe cool down prior to washing.

DO NOT exceed the probe's internal sensor limit of 212°F / 100°C or the ambient sensor limit of 527°F / 275°C. Temperatures above these maximums may damage the probe.

DO NOT expose the MEATER charging unit to moisture. Keep it covered in inclement weather, and do not put it in the sink.

Store the probe in a dry, cool place when not in use. This product is only designed for use in food. Use it only for its intended purpose.

Sharp Point Hazard


Always keep the MEATER probe pointed away from fingers and body. Contact may result in injury. Keep out of reach of children.

Getting Started


Before using your MEATER ensure the product has been charged and you have reviewed the important safety information below.
If you need any assistance using your MEATER device or have any questions please check out our Support Wizard and FAQ. If you need to speak to a member of our dedicated support team you can use the Support Wizard to help navigate you to the correct team.

Support

Step-by-step troubleshooting and customer support

FAQ

Answers to our most common concerns

Contact Us

Business enquiries, press and influencers

What is the maximum temperature MEATER can be used at?


If you need any assistance using your MEATER device or have any questions please check out our Support Wizard and FAQ. If you need to speak to a member of our dedicated support team you can use the Support Wizard to help navigate you to the correct team.

Important Safety Information


Charcoal Grill Cooking
Always Insert MEATER Probe passed the safety notch.

Ensure the MEATER is firmly inserted and not loose before cooking.

DO NOT cook with MEATER if the MEATER probe can't be inserted past the insertion notch.

Always wash your hands after handling raw meat
Place meat containing MEATER over indirect heat on your grill.

DO NOT cook with MEATER over direct heat (directly over the coals).

DO NOT remove your MEATER until after removing the meat from the grill

Carefully remove the meat from the grill when prompted by the MEATER app.

DO NOT remove the MEATER from the meat while on the grill.
Ensure the ambient temperature has reduced to safe levels before removing the MEATER probe.

If the probe is difficult to remove, pull and twist the ambient end. DO NOT bend the probe against the meat.

Always remove the MEATER probe before searing.
Once MEATER is removed, you can reverse sear your steak over direct heat (above the coals) on your grill, for a delicious finish.

DO NOT sear your meat with a MEATER probe inserted.
Once your meat is seared, serve and enjoy!

General Information

Information For the User


Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the users’ authority to operate the equipment.

MEATER Charger Model Number: MT-CH01 MEATER Probe Model Number: MT-PR00 FCC ID: 2AI5IMTPR Patents: meater.com/patents MEATER Probe IC: 24713-MTPR00 CAN ICES-3 (B)

FCC Statement

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Federal Communication Commission Interference Statement

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.

FCC Radiation Exposure Statement

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.

The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Apption Labs is under license. Other trademarks and trade names are those of their respective owners.

Limited Warranty And Return Policy


Apption Labs hereby warrants that the MEATER Plus is free from defects in parts, materials, and workmanship under normal use and maintenance for a period of two (2) years if purchased in the EU, Great Britain, Canada, Australia, and New Zealand; and one (1) year in the USA and all other countries from the date of original purchase. This warranty does not include shipping charges associated with any warranty parts or products.

Apption Labs shall not be liable under this or any implied warranty for incidental or consequential damages. This warranty gives the retail customer specific legal, rights and the customer may have other rights which vary by state and country.

This warranty shall be void if the MEATER product is not assembled or operated in accordance with the provided user instructions; the product is resold or traded to another owner; components or accessories not compatible with the product have been used; the product has been used in commercial or food service application; or the user has abused or otherwise failed to maintain the product.

To process a warranty claim, Apption Labs may require proof of your purchase. You should retain your sales slip or invoice.

Full warranty and return policy can be found on our online website, meater.com/warranty-returns.

Full company policies can be found on our online website, meater.com/support and supersedes any information found in this user guide. Should any repairs or servicing under this warranty be required by you during the limited warranty term, please contact the Customer Happiness Team at meater.com/support.

Please select your product to view its manual